Bus Cable

Bus cable

Designed specifically for WRTL, the cable is used exclusively with the i-TunneL® control systems.

The data-bus network comprises LS0H cable and IP68 connectors and meets the strictest requirements of the RS-485 protocol for EMI protection. This is used to create a robust and reliable single layer, plug-and-play network, providing the vital communications link between the B-ScoutMaster and the B-Scout controllers.

All data-bus cabling is supplied to customer specified lengths and is fully factory prepared and tested to the highest standard. The cables are formed into assemblies including IP68 plugs and sockets which mate directly with the WRTL range of tunnel luminaires.

Key Features

Used in conjunction with the i-TunneL® lighting control and monitoring system, the RS-485 Bus Cable is specifically designed for the arduous conditions common to the road tunnel environment. The strict specifications on shielding against electromagnetic interference and electrical noise ensure unsurpassed reliability. Coupled with its easy to install plug-and-play connectors, the cable allows the installer to quickly create an uncomplicated single layer communications network without any requirement for specialist engineers. 

Features & Benefits

  • Durable, single twisted pair cable
  • Thermoplastic, halogen-free sheath
  • High levels of EMI protection
  • Developed specifically for hostile tunnel environments
  • Industrial grade shielding
  • Impedance and capacitance matched for RS-485 applications
  • Suitable for use with the i-TunneL® plug-and-play systems
  • Provides communications up to 4.8km* from the B-ScoutMaster and up to 1000* B-Scouts
  • Single layer network, with only one hardware and one software protocol.
  • No specialist engineers required
  • Fast tool-free replacement of damaged cables without halting the control system

* - With the use of three repeater units

Example Topology

Standard single layer loop-in-loop-out network topology; Only one communications/hardware protocol throughout the whole installation.

Installation Considerations

The WRTL RS-485 data bus cable provides high levels of EMI protection, nevertheless separation between power and communications cables is considered good practise and should be achieved wherever possible. It is acceptable to run both the power and bus cables on the same tray work albeit clipped separately. Should the bus cable need to cross the power cable loom this should be done at right angles with spacing between. It is imperative that the bus is not run in close proximity to the radio redistribution cabling and certainly not fixed to the same cable tray.

Outer Sheath Specification

Polyolefinic based thermoplastic compound containing a fire retardant system that contributes to give the cable self-extinguishing properties without halogenic acids evolution; furthermore, toxic and corrosive gas emissions and smoke generation are particularly reduced. These characteristics make the compound suitable in all applications where the fire behaviour of the cables is of prime importance.

Options

Various assembly lengths available.

Technical Data

Conductors
Flexible tinned copper stranded
Insulation
Foam Polyethylene
Shield
Aluminium foil 100% + 22AWG TC drain wire + overall TC braid 90%
Jacket
Low smoke zero halogen – orange (LS0H)
Nominal OD
7.67mm
Service Temperature
-5oC to +60oC
Standards
IEC60332-1 - Flame resistant for single cables
IEC60332-3 - Flame resistant for bunched cables
IEC61034 - Low smoke generation
IEC60754.1- Negligible halogen gas generation

Plug & Socket Connectors

Durability
250 matings & unmatings
Vibration Resistance
Per CEI 60512-4
Thermal Shock
Per MIL-STD1344 method 1003
Insulation Resistance
5000MΩ min
Test Potential
2000VAC
Operating Temperature
-40oC to +105oC
Flammability Rating
UL94V0 and NFF16101 level 2
Sealing (mated)
IP68 – per IEC60529
UV
Resistant
Housing material
Thermoplastic

Dimensions & Range

Type No.
Description
IT-RS485-TSS1CS
RS-485 Single pair trunk bus cable
IT-RS485-CA3LD-FITTED
RS-485 Flying lead terminal socket
IT-RS485-CA3LS-FITTED
RS-485 Flying lead terminal plug

Associated Products

IT-RS485-1CHRE - Single channel RS-485 bus repeater unit

Data sheet

Login to view data sheet.