For use in
The 2811/2 luminaire series is best suited to road tunnels and underpasses requiring a mixture of fluorescent and HID lighting. The luminaires can be mounted over-lane either against the tunnel soffit or on a hung support system, or alternatively along the cornices of the tunnel mounted at a pre-determined angle. The luminaires are suitable for both interior and boost lighting applications, providing a complete and consistent lighting scheme.
Key features
The 2811 and 2812 tunnel luminaires are a proven guarantee for reliable, effective tunnel lighting. Ideally suited to low lighting level requirements where headroom space is an issue, the 2811/2 will always deliver. Formed from aluminium extrusion, the luminaire is available in several module lengths and compatible with a wide variety of linear fluorescent and low wattage HID lamps. The intelligent design makes installation and maintenance a quick and simple exercise.
- Fully compliant construction – designed and built to EN 60598
- Fluorescent and HID types available
- Robust sealing technique provides assured IP66 protection
- Longitudinal closing system provides even pressure along length of luminaire
- Tool-free access
- Simple maintenance
- Impact resistant to IK09
- Universal mounting along full length of luminaire with front access
- Reduced support requirements by employing modulisation option
- Total isolation from support structure eliminates corrosion caused by dissimilar metals
- Extensive corrosion protection systems employed, including chromation to 6+ level
- Will accept i-TunneL® Lighting Control System if specified
- Excellent optical performance from symmetrical and asymmetrical linear optics
Technical data
|
Ingress Protection
|
IP66 – EN 60598/EN 60529
|
|
Impact Resistance
|
IK09 – EN 50102
|
|
Fire Resistance
|
Class 1 – NEN 6065
|
|
Housing
|
2.5mm extruded aluminium EN573-3, AIMg Si 0.5
|
|
Sealing
|
EPDM - fluorescent
Silicone - HPS lamps
|
|
Cover
|
Thermally toughened glass (DIN 12150) in an extruded/welded alum. frame
|
|
Filter
|
Polyamide, pressure equalising, filter (IP66)
|
|
Closing Clips/Hinge
|
Aluminium extruded closing latch, zinc coated stainless steel hinges, 1.4310 (DIN 17224)
|
|
Gear Tray
|
Thermally galvanised steel plate; hinged for fluorescent, keyhole slot fixings for HID
|
|
Voltage
|
230VAC 50Hz Class 1
|
|
Cable Connection
|
Fluorescent: 3-5 x 4mm2 plug/socket - HID 3-5 x 6mm2 terminal block
|
|
Lamps
|
T8 36-58W, HID 50-100W, T5-49/80W
|
|
Optics
|
High quality anodised aluminium, sym. and asym.
|
|
HID Gear
|
Conventional ballast thermal cut-out, compensated (cos phi > 0.85)
|
|
Fluorescent Gear
|
Electronic (cos phi > 0.95)
|
|
Cable Entry
|
Polyamide gland M20, suitable for cable dia. 10-14mm
|
|
Finish
|
High quality pre-treatment and polyester powder coated, RAL 5007 (blue) minimum 65mm
|
|
Mounting
|
4 aluminium extruded clamps (AIMg Si 0.5) for M8 bolt
|
|
Ambient Temperature
|
Fluorescent lamps -15oC up to 40oC HID lamps -25oC to 40oC
|
Mounting Details
Simple support structure formed from a proprietary channel system, with luminaire fixed from the front using the supplied clamps. The clamping system allows movement in two axis for accurate positioning (prior to fixing) and affords complete isolation from the support structure.

Opening & Closing
Fast opening and closing system with two latches running the length of the luminaire for tool-free access and life-time sealing.
Options
-
Other lamps on request
-
Alternative cable entry positions & quantity
-
Flying lead cable(s) pre-assembled
-
Lamps supplied installed
-
Electronic HID gear
-
Preparation for control & monitoring system
-
Louvre System
-
Coupling parts for mounting in continuous line
-
Project specific luminaire coding
-
Alternative RAL colours
-
Inclusion of double pole cover switch
-
Multiple ‘modules’ per luminaire length
Dimensions and weights
Single Fluorescent
Twin Fluorescent
Single HID
End View (all types)
|
Type No.
|
Lamps
|
‘L’
|
‘W’
|
‘H’
|
Weight (kg)
|
|
281101.nnn
|
1 x T8-36
|
1285
|
240
|
98
|
16
|
|
281101.nnn
|
1 x T8-58
|
1585
|
240
|
98
|
18
|
|
281102.nnn
|
1 x T5-49
|
1585
|
240
|
98
|
18
|
|
281102.nnn
|
1 x T5-80
|
1585
|
240
|
98
|
18
|
|
281122.nnn
|
1 x HID-70
|
489
|
240
|
98
|
10
|
|
281112.nnn
|
1 x PLL-80
|
804
|
240
|
98
|
12
|
|
281231.nnn
|
2 x T8-36
|
1285
|
354
|
98
|
18
|
|
281231.nnn
|
2 x T8-58
|
1585
|
354
|
98
|
20
|
|
281232.nnn
|
2 x T5-49
|
1585
|
354
|
98
|
20
|
|
281232.nnn
|
2 x T5-80
|
1585
|
354
|
98
|
20
|
nnn – Last 3 digits define project specific requirements, e.g. optic type, wattage etc
Associated Products
2816 Series - Tunnel luminaire with point source 3D optics in single and twin HID types
2815 Series - Linear optic tunnel luminaire with multiple HID and fluorescent lamps
Order codes
Lamp Codes:
T5 Fluorescent tubular 16mm
T8 Fluorescent tubular 26mm
HID High intensity discharge tubular ‘T’ or elliptical ‘E’
Download a brochure here